The instrumentation will power the load cell. The mV/V signal coming back from the load cell is converted by the indicator and displays the force in a unit (e.g.: Kg, kN, lb - customers choice). The indicator will need to be mounted in to a case or control rack for safe use.
The load cell and instrumentation will require calibrating together for the system to work correctly. This is done by applying a known force to the load cell and the instrument's gain to be set.

MICROPROCESSOR BASED INDICATOR

Strong Anodized NEMA4X-IP56 ALUMINUM 1/8 DIN CASE Compact Design
Provides Excitation to Transducers or Sensors
Accept DC mV/V, V, mA Signal
Proportional Analog Output V or mA
Easy to Program using 4 Buttons
Front Panel Shunt Calibration
User Programmable High & Low Set Point
Standard No-Output or Relay Output
Optional 8-Step Output, RS232, or BCD Output Available
KEY FEATURES
 Display: 4 ½ Digit 7-Segment Red LED Display
 Sampling Rate: 15 Samples per Second
 Accuracy: ±0.02% of Full Scale
 Peak Hold: Display Peak Reading When Active
 Data Protection: Prevent Accidental or
 Unauthorized change of data
 Power Supply: 85V-245V AC
 Connection Type: Screw Terminal
 Operating Temperature: 32ºF to 122ºF (0ºC to 50ºC)
 Storage Temperature: -40ºF to 85ºF (-40ºC to 30ºC)
GENERAL FEATURES
Strain Gauge, 
Load Cells, 
Pressure Transducers, 
Torque Transducers, 
Distance Measurement, 
Temperature Measurement, 
Flow Meter,
Potentiometer, etc.
APPLICATIONS

for Strain Gauge And DC Voltage/Current Transducers

 
Accucon4100
   Accucon4150    
Accucon4200
Accucon4250
Input Type
1 to 3mV/V
(Controlled by
DIP Switch)  
 1 to 3mV/V
(Controlled by DIP Switch)
0~5V/0~10V
0~20mA/4~20mA
0~5V/0~10V
0~20mA/4~20mA
Analog Output
 0~5V/0~10V
0~20mA/4~20mA
No Output 
 0~5V/0~10V
0~20mA/4~20mA
 No Output
Control Output
 High/Low Relays
(Open Collector, BCD, and RS-232 Available as Option)
No Output 
High/Low Relays
(Open Collector, BCD, and RS-232 Available as Option) 
 No Output
Sensor Excitation
5V DC
5V DC
10V DC , 24V DC
(±15V DC Available as Option)
10V DC , 24V DC
(±15V DC Available as Option)
Date Hold
 
Freeze Display When Active
 
No Data Hold
Freeze Display When Active